Operating conditions
Describe the test, measured quantity, temperature and installation space.
Airbag deployment test system
An integrated system for temperature conditioning, controlled firing, electrical measurements and synchronized high-speed imaging.
Images illustrate appearance. Confirm range, interfaces and custom options with an engineer.
TECHNICAL DATA
Airbag Deployment Test System
Airbag deployment test system
| Firing channels | 2 independent power supplies and channels |
|---|---|
| Low-range firing current | 1.2–1.5 A; duration ≥2 ms |
| High-range firing current | 1.75–2.05 A; duration ≥0.5 ms |
| External trigger outputs | At least 4 BNC outputs |
| Thermocouple inputs | At least 4 inputs and 4 thermocouples |
| Temperature measurement | −40 °C to +110 °C; accuracy ±1 °C |
| Temperature recording | Sampling ≥1 Hz; continuous recording up to 24 h |
| Electrical measurements | Firing current, voltage and pre/post-test module resistance |
| Pulse adjustment | Independently adjustable start time, duration and amplitude |
| Protection and alarms | Short-circuit protection; short/open circuit and resistance-limit alarms |
| Peripheral control | LED lighting, exhaust and environmental-chamber door control |
| Camera trigger | Triggered by PAB firing signal; external trigger compatibility required |
| Workstation | 1 workstation; ≥16 GB RAM; 2 displays |
| Test records | Specimen data, temperature/humidity, pulse curves, resistance and deployment timing |
| Test modes | Automatic firing after temperature conditioning / ambient-temperature firing |
Specifications follow the supplied airbag system material. Confirm displays, interfaces and interlocks for the project. System overview ↗
SELECTION SUPPORT
Describe the test, measured quantity, temperature and installation space.
Confirm range, output signals, acquisition equipment and interfaces.
Agree cable lengths, connectors, calibration and other project options.
LET’S TALK
Tell us about your application, measurement points and technical requirements.