GAPIGAPISensor · System · Service中文 ↗

GAPI / AIRBAG DEPLOYMENT

Airbag deployment test system

Integrate firing control, temperature logging, current and voltage acquisition, and high-speed camera triggering.

INTEGRATED TEST SYSTEM

From firing control to test records

Support automatic firing after temperature conditioning and ambient firing outside the chamber, with independent channels, electrical measurement, temperature monitoring and external triggers.

Discuss your system ↗

TEST WORKFLOW

Coordinate the complete test workflow

01

Prepare

Identify specimens, firing channels and temperature conditions.

02

Synchronize

Set pulse parameters and coordinate external trigger timing.

03

Capture

Record video, current, voltage and temperature data.

04

Trace

Save specimen information, electrical curves and deployment timing.

SYSTEM OVERVIEW

System components and specifications

System images and specifications follow the supplied project material. Confirm the final configuration for each project.

Airbag deployment test system
Firing channels2 independent power supplies and channels
Low-range firing current1.2–1.5 A; duration ≥2 ms
High-range firing current1.75–2.05 A; duration ≥0.5 ms
External trigger outputsAt least 4 BNC outputs
Thermocouple inputsAt least 4 inputs and 4 thermocouples
Temperature measurement−40 °C to +110 °C; accuracy ±1 °C
Temperature recordingSampling ≥1 Hz; continuous recording up to 24 h
Electrical measurementsFiring current, voltage and pre/post-test module resistance
Pulse adjustmentIndependently adjustable start time, duration and amplitude
Protection and alarmsShort-circuit protection; short/open circuit and resistance-limit alarms
Peripheral controlLED lighting, exhaust and environmental-chamber door control
Camera triggerTriggered by PAB firing signal; external trigger compatibility required
Workstation1 workstation; ≥16 GB RAM; 2 displays
Test recordsSpecimen data, temperature/humidity, pulse curves, resistance and deployment timing
Test modesAutomatic firing after temperature conditioning / ambient-temperature firing

Records include specimen information, temperature and humidity, firing curves, resistance and deployment time. Short-circuit protection and short/open-circuit and resistance alarms are included. Confirm displays, interfaces and interlocks for the project.

LET’S TALK

Turn your test requirements into a suitable configuration

Tell us about your application, measurement points and technical requirements.

Talk to an engineer ↗
↑